Automation Spare Part

6AG1241-1CH30-5XB1

Send the exact MLFB, required quantity and delivery destination to request supply details for this Siemens automation spare part.

Product Specifications

Model / MLFB
6AG1241-1CH30-5XB1
Product Category
SIPLUS S7-1200 Systems
Product Code
6AG1241-1CH30-5XB1
Dimensions
8.2 × 5 × 2.8 cm
Weight
0.033 kg
Lifecycle
Active Product
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
View products in this category

Product Description

Key Features

  • RS-485 communication board: CB 1241 RS 485 for the SIPLUS S7-1200 range.
  • Integrated protocol driver support: Freeport, ASCII, Modbus RTU master, Modbus RTU device, and USS.
  • Terminal block connection: Supplied with a terminal block connection for installation.
  • Conformal coating: Conformal coating is provided for the board.
  • Diagnostics function: Diagnostics function: Yes.

Applications

  • RS-485 network connection: Provides RS-485 communication in a SIPLUS S7-1200 setup.
  • Freeport serial communication: Supports Freeport communication for point-to-point serial data exchange.
  • Modbus RTU communication: Supports Modbus RTU master and Modbus RTU device operation.

Technical Summary

Product type designation CB 1241 RS 485
Based on 6ES7241-1CH30-1XB0
Input current, from backplane bus 5 V DC, typ. 50 mA
Power loss, typ. 1.5 W
Freeport – Bits per character 7 or 8
Freeport – Number of stop bits 1 (Standard), 2
Freeport – Parity No parity (standard); even, uneven, mark (parity bit always 1); space (parity bit always 0)
Modbus RTU master – Address area 1 through 49 999 (Standard Modbus addressing)
Modbus RTU master – max. number of devices 247; slave numbers 1 through 247, per MODBUS network segment maximum 32 devices, additional repeaters needed to expand the network to maximum configuration
Diagnostics function Yes

Frequently Asked Questions

What is Siemens 6AG1241-1CH30-5XB1?

It is a SIPLUS S7-1200 CB 1241 RS-485 communication board.

Which communication functions does 6AG1241-1CH30-5XB1 support?

It supports Freeport, ASCII, Modbus RTU master, Modbus RTU device, and USS.

What are the key electrical specifications of 6AG1241-1CH30-5XB1?

Input current from backplane bus 5 V DC is typ. 50 mA, and power loss is typ. 1.5 W.

What is the maximum cable length for the point-to-point connection?

The cable length, max. is 1 000 m.

What should be checked before selecting this board?

Check the RS-485 requirement, the needed protocol driver, and the installation details such as the terminal block connection and the 1 000 m cable length, max.