Key Features
- CPU 1510SP-1 PN: Distributed controller with 25 ns bit performance and 200 KB work memory for program plus 1 MB for data.
- 1st interface: PROFINET IRT: 1st interface includes PROFINET IRT with a 3-port switch and 3 ports in total, with BusAdapter required for port 1 and 2.
- Engineering and diagnostics: STEP 7 TIA Portal configurable/integrated, with I&M data, SysLog, web server, and diagnostics indication LEDs.
- Selection and maintenance: SIMATIC Memory Card required, 1 slot for SIMATIC memory card, FW update possible, and hot swapping supported as Multi-hot swapping.
Applications
- PROFINET-based controller integration: Integration of the CPU into a PROFINET network with PROFINET IO Controller and PROFINET IO Device functions.
- Distributed I/O system connection: Connection of distributed I/O via PROFINET, PROFIBUS communication modules, or AS-i master modules or links.
- Engineering and commissioning: Engineering, configuration, online access, status/control, forcing, traces, and test commissioning in STEP 7 TIA Portal and related functions.
Technical Summary
| Product type designation | CPU 1510SP-1 PN |
|---|---|
| Based on | 6ES7510-1DK03-0AB0 |
| Conformal coating | -40…+60 °C |
| Work memory for program | 200 KB |
| Work memory for data | 1 MB |
| 1st interface | PROFINET IRT with 3-port switch |
| Bit performance | 25 ns |
| SIMATIC Memory Card required | Yes |
| BusAdapter required for port 1 and 2 | Yes |
| Supply voltage, rated value (DC) | 24 V |
| Supply voltage, permissible range | 19.2 V … 28.8 V |
| Reverse polarity protection | Yes |
| Power loss, typ. | 3.5 W |
| Number of PROFINET interfaces | 1 |
| Number of PROFIBUS interfaces | 1; Via CM DP module |
| PROFINET IO Controller | Yes |
| PROFINET IO Device | Yes |
| Open IE communication | Yes; Optionally also encrypted |
| Modbus | Yes; MODBUS TCP |
Frequently Asked Questions
What is Siemens 6AG1510-1DK03-2AB0 exactly?
It is a SIPLUS ET 200SP CPU 1510SP-1 PN based on 6ES7510-1DK03-0AB0.
Which interface does this CPU provide for network connection?
It includes 1st interface: PROFINET IRT with 3-port switch, and the CPU has 1 PROFINET interface.
What memory and processing data define this CPU?
It has 200 KB work memory for program, 1 MB work memory for data, and 25 ns bit performance.
What should be checked before selection and installation?
Check the required SIMATIC Memory Card, the BusAdapter requirement for port 1 and 2, the 24 V DC supply, and the 19.2 V … 28.8 V permissible range.