Key Features
- Interface module for ET 200M: IM 153-4 PN HF for ET 200M connection.
- Module capacity: Supports max. 12 S7-300 modules per DP device interface.
- PROFINET IO functions: Bus protocol/transmission protocol: PROFINET IO with IRT, prioritized startup, shared device, and PROFINET system redundancy (S2).
- Communication and diagnostics: TCP/IP, SNMP, LLDP, ping, and ARP are supported, with LINK LED, RX/TX LED, and module diagnostics indication.
- Electrical and environmental data: Rated value (DC): 24 V; permissible range: 20.4 V to 28.8 V; IP degree of protection: IP20; operating temperature: -40 °C to 70 °C.
- Physical design: Width 40 mm, height 125 mm, depth 118 mm, weight approx. 215 g.
Applications
- ET 200M connection: Connection of ET 200M as a DP device interface.
- Shared-device network integration: Operation in a shared device setup with up to 2 IO Controllers.
Technical Summary
| Product type designation | IM 153-4 PN HF |
|---|---|
| Based on | 6ES7153-4BA00-0XB0 |
| Vendor identification (VendorID) | 002AH |
| Device identifier (DeviceID) | 0302H |
| Rated value (DC) | 24 V |
| Permissible range, lower limit (DC) | 20.4 V |
| Permissible range, upper limit (DC) | 28.8 V |
| Current consumption, max. | 600 mA; with 24 V DC supply |
| Output current for backplane bus (5 V DC), max. | 1.5 A |
| Number of modules per DP device interface, max. | 12 |
| Bus protocol/transmission protocol | PROFINET IO |
| TCP/IP | Yes |
| SNMP | Yes |
| Shared device | Yes |
| Number of IO Controllers with shared device, max. | 2 |
| IP degree of protection | IP20 |
| Ambient temperature during operation, min. | -40 °C; = Tmin; Startup @ -25 °C |
| Ambient temperature during operation, max. | 70 °C; = Tmax; Tmax > 60 °C output current for backplane bus (5 V DC) max. 0.9 A |
Frequently Asked Questions
What is Siemens 6AG1153-4BA00-7XB0?
It is a SIPLUS ET 200M IM 153-4 PN HF interface module.
How many modules can it support?
It supports max. 12 S7-300 modules per DP device interface.
Which communication and diagnosis functions are included?
It supports PROFINET IO, TCP/IP, SNMP, LLDP, ping, ARP, IRT, prioritized startup, shared device, and PROFINET system redundancy (S2).
What electrical supply and protection data should be checked before selection?
Rated value (DC) is 24 V, with a permissible range of 20.4 V to 28.8 V; IP degree of protection is IP20.
What are the operating temperature limits?
Operating temperature is -40 °C to 70 °C, with startup at -25 °C.