Automation Spare Part

3RW4456-6BC44

Send the exact MLFB, required quantity and delivery destination to request supply details for this Siemens automation spare part.

Product Specifications

Model / MLFB
3RW4456-6BC44
Product Category
SIRIUS Control Systems
Product Code
3RW4456-6BC44
Dimensions
59 × 77 × 48 cm
Weight
65.5 kg
Lifecycle
Start of final year of support
Availability
in stock
Lead Time
Confirmed with quotation
Product Attachment
Download Datasheet
View products in this category

Product Description

Key Features

  • SIRIUS soft starter: Product designation: Soft starter.
  • Integrated bypass contact system: Built-in bypass contact system for the device.
  • Motor protection functions: Motor overload protection, evaluation of thermistor motor protection, and intrinsic device protection.
  • Current control: Adjustable current limitation and inside-delta circuit capability.
  • Control and switching technology: Thyristors and product component motor brake output.

Applications

  • Motor soft starting: Soft starting for a motor in standard circuit or inside-delta circuit operation.

Technical Summary

Product designation Soft starter
Integrated bypass contact system Yes
Thyristors Yes
Motor overload protection Yes
Adjustable current limitation Yes
Inside-delta circuit Yes
Operational current at 40 °C rated value 780 A
At 400 V – at standard circuit at 40 °C rated value 450 kW
Operating voltage at standard circuit rated value 200 … 460 V
Control supply voltage 1 at AC at 50 Hz rated value 230 V
Type of electrical connection for main current circuit busbar connection
Type of electrical connection for auxiliary and control circuit screw-type terminals

Frequently Asked Questions

What is Siemens 3RW4456-6BC44?

It is a SIRIUS soft starter.

What operating voltage does 3RW4456-6BC44 use?

Operating voltage at standard circuit rated value: 200 … 460 V.

What is the control supply voltage for 3RW4456-6BC44?

Control supply voltage 1 at AC: 230 V.

What type of connections does 3RW4456-6BC44 use?

Main current circuit: busbar connection. Auxiliary and control circuit: screw-type terminals.

What protection and control functions are included in 3RW4456-6BC44?

It includes integrated bypass contact system, motor overload protection, evaluation of thermistor motor protection, intrinsic device protection, and adjustable current limitation.

Product Enquiry

Need Help With 3RW4456-6BC44?

Email the model, required quantity and destination. For an installed or discontinued unit, include the hardware version and available nameplate details.

Submit RFQ